Revision as of 16:10, 2 May 2018
The Technical Handbook – Domestic, published by Scottish Ministers to provide guidance on the Scottish building standards suggests there are 4 main types of fire detector used in dwellings:
- Optical smoke alarms.
- Ionisation smoke alarms.
- Multi-sensor alarms.
- Heat alarms.
Alarms may be hard wired or battery operated, and may be interconnected so that if one detector is triggered, all interconnected alarms sound.
It is important that the right type of fire detector is used for different situations, as false alarms can result in occupants ignoring or disabling fire detection and fire alarm systems.
The most common causes of false alarms are:
- Fumes from cooking.
- Steam from bathrooms, shower rooms and kitchens.
- Tobacco smoke.
- Dust.
Multi-sensor alarms (or multi-criteria alarms) detect more than one fire phenomena, for example optical and heat detection. They may also include other detection capabilities, such as carbon monoxide detection.
A multi-sensor alarm provides early warning of fire and can significantly reduce the number of unwanted false alarms in certain circumstances.
Research by BRE, published in 2014, suggested that replacement of existing detectors in Kings College London with intelligent multi-sensor detectors could reduce false alarms by 69%, and that in the general building stock, the increased use of multi-sensor detectors may avert false alarms from common causes such as cooking fumes, steam and so on. Ref The causes of false fire alarms in buildings.
Intelligent multi-sensor alarms are independently addressed and continuously monitored to verify correct operation. They may also have adjustable sensitivity settings and drift compensation to account for environmental conditions. This can help identify when an alarm is genuine, as opposed to resulting from a maintenance issue or incorrect setting.
In dwellings, multi-sensor alarms are recommended in hallways and stairwells adjacent to bathrooms or shower rooms to reduce the number of unwanted false alarms.
For more information, see the BS 5839 series of standards for fire detection and fire alarm systems for buildings.
Find out more
Related articles on Designing Buildings Wiki
- Carbon monoxide.
- Carbon monoxide detector.
- Fire detection and alarm system.
- Fire.
- Heat alarm.
- Intruder alarm.
- Ionisation smoke alarms.
- New requirements for fire detection and alarm network systems IP 12 13.
- Optical smoke alarm.
- Smoke detection in high ceiling spaces.
- Smoke detector.
- The causes of false fire alarms in buildings.
Featured articles and news
Infrastructure that connect the physical and digital domains.
Harnessing robotics and AI in challenging environments
The key to nuclear decommissioning and fusion engineering.
BSRIA announces Lisa Ashworth as new CEO
Tasked with furthering BSRIA’s impressive growth ambitions.
Public buildings get half a million energy efficiency boost
£557 million to switch to cleaner heating and save on energy.
CIOB launches pre-election manifesto
Outlining potential future policies for the next government.
Grenfell Tower Inquiry announcement
Phase 2 hearings come to a close and the final report due in September.
Progress from Parts L, F and O: A whitepaper, one year on.
A replicated study to understand the opinion of practitioners.
ECA announces new president 2024
Electrical engineer and business leader Stuart Smith.
A distinct type of countryside that should be celebrated.
Should Part O be extended to existing buildings?
EAC brands heatwave adaptation a missed opportunity.
Definition of Statutory in workplace and facilities management
Established by IWFM, BESA, CIBSE and BSRIA.
Tackling the transition from traditional heating systems
59% lack the necessary information and confidence to switch.
The general election and the construction industry
As PM, Rishi Sunak announces July 4 date for an election.
Eco apprenticeships continue help grow green workforce
A year after being recognised at the King's coronation.
Permitted development rights for agricultural buildings
The changes coming into effect as of May 21, 2024.