Leaks in buildings
The term ‘leak’ refers to the accidentally loss or admission of something through a hole, crack, or some other permeability. It most commonly relates to liquids or gases, but might also refer to some solids that can behave in a fluid manner, such as sand.
In the construction industry, leaks might refer to:
- Penetrating damp, allowing moisture through roofs, walls, floors, windows and so on. This can cause decay to the building fabric, mould growth, mildew and so on. For more information see: Penetrating damp in buildings.
- Leaking pipework, such as water pipes, refrigeration pipes, gas or oil pipes, drainage pipework and so on. For more information see: Pipework defects, ventilation and airflow rates.
- Leaking ducts such as ventilation ducts.
- Leaking fixtures, fittings and equipment, such as taps, sinks, showers, washing machines and so on.
- Air infiltration through doors, windows and the fabric of the building, resulting in uncomfortable draughts and inefficiencies in heating, cooling and ventilation systems. The building regulations now require air permeability testing to prove that infiltration into new buildings is low. For more information see: Draughts in buildings and Air tightness in buildings.
- Failure of flood defences or drainage.
Leaks can result from:
- Poor workmanship, including poor repairs.
- Defective products or components, or failure of products or components (in particular problems with joints).
- Incorrect specification or design.
- Movement, such as settlement, thermal expansion and so on.
- Environmental influences such as wind, flood (and drainage problems), freezing and so on.
Because of the tendency for leaking materials to move, leaks can be difficult to detect, and their causes can be difficult to trace and rectify.
Leaks that go unrepaired can result in significant losses. A tap leaking just once every 6 seconds can discharge almost 100 litres in a month. In a review of water company performance published in 2019, it was reported that 3.17 billion litres of water leaks from the water distribution network every day in England and Wales (Ref https://wwtonline.co.uk/news/ccwater-criticises-three-companies-over-leakage).
Leaking water or mains gas can be very damaging and sometimes dangerous, whilst leaks of some refrigerants, oil and so on can be damaging to the environment.
When repairing leaks, it is important to identify the actual source of the leak, and to repair the problem that has caused it before repairing any of the subsequent damage that may have resulted from the leak.
NB Leakage can also refer to '...the leakage of benefits intended for a recipient group or area into another group or area.' Ref The Green Book, Central Government Guidance On Appraisal And Evaluation, Published by HM Treasury in 2018.
Note The 2020 Green Book suggests ‘Leakage is the extent to which effects “leak out” of a target area into others e.g. workers commuting into other areas to take up new employment opportunities.’
[edit] Related articles on Designing Buildings
- Air tightness in buildings.
- Approved document L.
- BREEAM Water leak detection.
- Damp in buildings.
- Draughts in buildings.
- Fit testing.
- How to waterproof a rooflight.
- Let us evolve our buildings from being passive structures to interactive and reactive systems.
- Penetrating damp in buildings.
- Pipework defects, ventilation and airflow rates.
- Refrigerants.
- Roofing repairs.
Featured articles and news
Infrastructure that connect the physical and digital domains.
Harnessing robotics and AI in challenging environments
The key to nuclear decommissioning and fusion engineering.
BSRIA announces Lisa Ashworth as new CEO
Tasked with furthering BSRIA’s impressive growth ambitions.
Public buildings get half a million energy efficiency boost
£557 million to switch to cleaner heating and save on energy.
CIOB launches pre-election manifesto
Outlining potential future policies for the next government.
Grenfell Tower Inquiry announcement
Phase 2 hearings come to a close and the final report due in September.
Progress from Parts L, F and O: A whitepaper, one year on.
A replicated study to understand the opinion of practitioners.
ECA announces new president 2024
Electrical engineer and business leader Stuart Smith.
A distinct type of countryside that should be celebrated.
Should Part O be extended to existing buildings?
EAC brands heatwave adaptation a missed opportunity.
Definition of Statutory in workplace and facilities management
Established by IWFM, BESA, CIBSE and BSRIA.
Tackling the transition from traditional heating systems
59% lack the necessary information and confidence to switch.
The general election and the construction industry
As PM, Rishi Sunak announces July 4 date for an election.
Eco apprenticeships continue help grow green workforce
A year after being recognised at the King's coronation.
Permitted development rights for agricultural buildings
The changes coming into effect as of May 21, 2024.