Drainage stack
The term ‘drainage stack’ or ‘drain stack’ is commonly used in the United States, and sometimes in commercial construction in the UK.
In very broad terms, it refers to a vertical pipe or stack that spans through one or more floors and into which drains from a property are connected to take waste water to a sewer. Branch drains run relatively horizontally from water closets, sinks, showers and so on to the vertical drainage stack which then connects to a relatively horizontal sewer at its lowest point. It may be referred to as a vent stack above the point that drains connect to it, as a drain stack below the point at which waste water drains into it and as a soil stack below the point at which sewage drains into it.
In the UK, particularly in domestic construction, it may be referred to as a soil vent pipe (SVP). Soil vent pipes allow the removal of waste from toilets, showers, baths, sinks and so on, while also allowing odours to be released above the building, via a stack vent, at a level that will not cause a nuisance. The pipe’s vent also allows air into the internal drainage system preventing a siphoning effect from occurring, and allowing free flow of waste water by gravity. An SVP may also be described as a soil stack pipe, drain waste vent or ventilated discharge pipe and is often seen on an outside wall of domestic buildings, but may be located internally.
For more information see: Soil vent pipe.
When installing drainage and ventilation pipework in high-rise buildings, traditional design standards dictate that a secondary ventilation stack has to be used to overcome air pressure changes. However, products such as the Polypipe Terrain P.A.P.A® and Pleura valves are a proven alternative to traditional secondary vented drainage systems. The P.A.P.A® (positive air pressure attenuation) valve is designed to react to and attenuate positive pressure transience within the drainage stack of high-rise developments providing a suitable venting solution for any multi-storey building.
For more information see: Secondary Ventilation Stacks in Tall Buildings.
[edit] Related articles on Designing Buildings Wiki
- Air admittance valve.
- Drainage.
- Fabricated drainage stacks.
- Greywater.
- Pumps and dewatering equipment.
- Rain gutter.
- Rainwater.
- Rainwater goods.
- Rainwater downpipe.
- Sanitary pipework.
- Secondary Ventilation Stacks in Tall Buildings.
- Sewer construction.
- Soil vent pipe.
- Soakaway.
- Sustainable urban drainage systems SUDS.
- Vacuum breaker.
- Wellpoint.
Featured articles and news
Infrastructure that connect the physical and digital domains.
Harnessing robotics and AI in challenging environments
The key to nuclear decommissioning and fusion engineering.
BSRIA announces Lisa Ashworth as new CEO
Tasked with furthering BSRIA’s impressive growth ambitions.
Public buildings get half a million energy efficiency boost
£557 million to switch to cleaner heating and save on energy.
CIOB launches pre-election manifesto
Outlining potential future policies for the next government.
Grenfell Tower Inquiry announcement
Phase 2 hearings come to a close and the final report due in September.
Progress from Parts L, F and O: A whitepaper, one year on.
A replicated study to understand the opinion of practitioners.
ECA announces new president 2024
Electrical engineer and business leader Stuart Smith.
A distinct type of countryside that should be celebrated.
Should Part O be extended to existing buildings?
EAC brands heatwave adaptation a missed opportunity.
Definition of Statutory in workplace and facilities management
Established by IWFM, BESA, CIBSE and BSRIA.
Tackling the transition from traditional heating systems
59% lack the necessary information and confidence to switch.
The general election and the construction industry
As PM, Rishi Sunak announces July 4 date for an election.
Eco apprenticeships continue help grow green workforce
A year after being recognised at the King's coronation.
Permitted development rights for agricultural buildings
The changes coming into effect as of May 21, 2024.