[edit] BSRIA Air Quality Hub
The air quality hub is a section of BSRIA to share knowledge members, professionals and the public about air quality, its importance in homes, schools, and workplaces, and how indoor air quality can be managed in buildings to limit occupant exposure to harmful contaminants.
[edit] What is air quality?
Air of good quality is air in which there are no known contaminants at harmful concentrations. Air pollution can have a negative impact on our health; from short term effects such as eye irritation and coughs to long term effects such as respiratory infections and cancer. The effect on health depends on the contaminant concentration and exposure time.
[edit] Indoor Air Quality (IAQ)
In the UK, people spend approximately 90% of their time indoors. The quality of indoor air is affected not only by outdoor pollution, but also by indoor sources and inadequate ventilation. Tobacco smoke, mould, and chemicals released from synthetic fabrics, paints, furnishings and household products are some of the sources of contaminants that make indoor air worse than outdoor air at times. Indoor air pollutants may be biological, such as dust mite faeces, mould spores, viruses and pollen, or chemical, such as carbon monoxide, ozone and volatile organic compounds.
Download the free BSRIA Indoor Air Quality Topic Guide.
[edit] How to assess indoor air quality
Given the impact of air quality on the health and wellbeing of building occupants, measuring IAQ is a vital step in managing the indoor environment to ensure that exposure to harmful contaminants is kept to a safe level.
Find out more about harmful contaminants at the BSRIA Blog.
To demonstrate how air quality can be monitored, BSRIA has installed air monitors throughout its UK premises and has made the live data publicly visible.
View the live data from BSRIA’s air monitoring initiative.
Indoor air quality sensors were installed throughout BSRIA’s offices and meeting rooms as part of the effort to support the wellbeing of staff, delegates to BSRIA training courses, and other visitors.
View BSRIA Instrument Solutions range of air quality instrumentation.
BSRIA Microclimate Team Leader, Calum Maclean, describes the process of monitoring air quality at BSRIA's premises in this video.
[edit] How to improve indoor air quality
Monitoring IAQ is just one of the steps required to effect a positive change in the indoor environment. Prior to installing the sensors, BSRIA indoor air quality specialists carried out an extensive investigation of its premises. This included measuring ventilation system volume airflow rates, verifying the air distribution within the building, and quantifying air changes per hour using carbon dioxide tracer gas tests.
This exercise provided an actual baseline dataset to establish if CO concentrations below 800ppm in line with the [https://www.rehva.eu/rehva-journal/chapter/co2-monitoring-and-indoor-air-quality Federation of European Heating, Ventilation and
Air Conditioning Associations REHVA] guidance on reliable indoor air quality could be maintained across the premises and in meeting rooms. The outcome of the measurements prompted the installation of additional local extraction fans to ensure safe and comfortable occupancy.
--BSRIA
[edit] Other reports and links:
BREEAM, LEED or WELL (WP 13/2020)
[edit] Related articles on Designing Buildings
- Air pollution index
- Air quality in the built environment
- Air Quality Taskforce
- At a glance - Indoor air quality
- BSRIA responds to UK Air Pollution Report.
- Bringing a breath of fresh air to the design of indoor environments.
- Construction dust
- Ensuring good indoor air quality in buildings
- Fresh air
- Health effects of indoor air quality on children and young people
- High pollution location
- Indoor air quality
- Indoor environmental quality
- Locating ventilation inlets to reduce ingress of external pollutants into buildings: A new methodology IP 9 14
- Mechanical ventilation's role in improving indoor air quality
- National Health Service Act of 2006
- Smog
- Sources of external pollution
- TSI Environmental dust monitoring system
- Ultra Low Emission Zone
- United Nations Economic Commission for Europe UNECE
Featured articles and news
Infrastructure that connect the physical and digital domains.
Harnessing robotics and AI in challenging environments
The key to nuclear decommissioning and fusion engineering.
BSRIA announces Lisa Ashworth as new CEO
Tasked with furthering BSRIA’s impressive growth ambitions.
Public buildings get half a million energy efficiency boost
£557 million to switch to cleaner heating and save on energy.
CIOB launches pre-election manifesto
Outlining potential future policies for the next government.
Grenfell Tower Inquiry announcement
Phase 2 hearings come to a close and the final report due in September.
Progress from Parts L, F and O: A whitepaper, one year on.
A replicated study to understand the opinion of practitioners.
ECA announces new president 2024
Electrical engineer and business leader Stuart Smith.
A distinct type of countryside that should be celebrated.
Should Part O be extended to existing buildings?
EAC brands heatwave adaptation a missed opportunity.
Definition of Statutory in workplace and facilities management
Established by IWFM, BESA, CIBSE and BSRIA.
Tackling the transition from traditional heating systems
59% lack the necessary information and confidence to switch.
The general election and the construction industry
As PM, Rishi Sunak announces July 4 date for an election.
Eco apprenticeships continue help grow green workforce
A year after being recognised at the King's coronation.
Permitted development rights for agricultural buildings
The changes coming into effect as of May 21, 2024.